TR/TA-01 series:

  • Version : relative and absolute pressure
  • Measurement range :  -1 to 400 bar
  • Technology : Thick enameled strain gauge on ceramic
  • Ouput : 4-20 mA - 2 wires
  • Global error : +/-0.2% FS
  • Setting : Zero and span
  • Agreement : ATEX 2014/34 UE

Options

  • Intrinsic Safety
  • Flush diaphragm
  • Oygen cleaning
  • Reinforced Max. P.
  • Rangeability from 50 to 100% FS

TR/TA-02 series:

  • Version : relative and absolute pressure
  • Measurement range :  -1 to 400 bar
  • Technology : Thick enameled strain gauge on ceramic support
  • Ouput : 4-20 mA - 2 wires
  • Global error : +/-0.2% FS
  • Setting : Zero and span
  • Agreement : ATEX 2014/34 UE

Specifications:

  • Stainless steel head and body (reinforced tightness)
  • Screw terminal connection
  • Axial or radial cable gland

Options:

  • Intrinsic Safety
  • Flush diaphragm
  • Oygen cleaning
  • Reinforced max-pressure
  •  Rangeability (50 to 100% FS)

Flush cell industrila type - TR/TA-22 series:

  • Version : elative and absolute pressure
  • Measurement range : -1 to 50 bar
  • Process connection : 1''BSPM, CLAMP or SMS
  • Technology : Thick enameled strain gauge on ceramic support
  • Output : 4-20 mA - 2 wires
  • Global error : ±0,2% FS
  • Setting : Zero and span
  • Agreement : ATEX 2014/34 UE

Specifications:

  • Flush ceramic cell
  • No retention area and no fluid filling
  • 316L stainless steel head and housing (reinforced tightness)
  • Terminal connection
  • Axial or radial cable gland

Options:

  •  Intrinsic Safety
  • Flush diaphragm
  • Oygen cleaning
  • Reinforced P. Max.
  • Rangeability of 50 to 100% FS