Inductive electromagnetic flowmeters are best suitable for flow measurements of fluids with electrical conductivity from 5 μS/cm (20 μS/cm for demineralized water). This flowmeters range offers high accuracy. Results measurement are independant of density, temperature and pressure.

Mehr Informationen
Detailinformationen

The operating principle of the electromagnetic flow meter is based on Faraday’s law of magnetic induction: The voltage induced across any conductor, as it moves at right angles through a magnetic field, is proportional to the velocity of that conductor.
The voltage induced within the fluid is measured by two diametrically opposed internally mounted electrodes.
The induced signal voltage is proportional to the product of the magnetic flux density, the distance between the electrodes and the average flow velocity of the fluid.
Fuji Electric offers 2 electromagnetic measurement solutions for all your liquids flow management : MAGFLO flowmeters and MAGNETOFLOW flowmeters

An economical solution for the water supply, irrigation and waste water drainage fields

  • Available for pipe diameters from 6 to 2000 mm,
  • Compact mounting (converter mounted on the measuring tube) or remote,
  • Several internal coatings of the measuring tube (PTFE, hard rubber, rubber) and several types of electrodes (AISI 316 Ti, Hastelloy CTM and Platinum) are available,
  • Version to use on hazardous area (M3000/M4000)
  • Stand-alone version (M5000) with battery power (up to 12 years of autonomy),
  • Extended communication options (HARTTM, PROFIBUS-DP, MODBUSTM, M-Bus, Ethernet etc.)

Mainly features

  • Accuracy  ±0,3%,
  • Flow range 0,03 – 12 m/s,
  • DN6 – DN500,
  • LCD display with backlight,
  • Power supply 92 – 275 VCA / 9 – 36 VCC,
  • P67 protection,
  • RS232 / RS485 Modbus® RTU in standard,
  • HART™, M-Bus, ETHERNET (Modbus® TCP/IP) in option.

Technical data

  • Power supply: 92-275 VAC (50 / 60 Hz), <10 VA optional 9-36 VDC
  • Accuracy: +/- 0,3% of m.v., +/- 2 mm/s
  • Repeatability: 0,1%
  • Flow range: 0,03 – 12 m/s
  • Conductivity: min. 5 µS/cm (20 µS/cm for demineralized water)
  • Flow direction: bi-directional
  • Programming: 3  buttons optional RS232
  • Interface: RS232, RS422/485, Modbus® RTU in standard
                    HART™, M-Bus, ETHERNET (Modbus® TCP/IP) in option
  • Analog output: 0/4 - 20 mA / 0-10 mA, flow direction is displayed upon a separate status output
  • Pulse output: 2 open collectors, passive 32 VDC, 0-100 Hz 100 mA, 100-10.000 Hz 20 mA, optional active
  • Frequency output: max. 10 kHz (open collector)
  • Status output: min/max. alarm, preselection, flow direction, error message, free configurable
  • Empty pipe detection: separate electrodeLow flow cut off0-10%
  • Housing: Powder coated aluminium die cast
  • Protection class: IP67
  • Cable insertion: 2 x M 20
  • Ambient temperature: -20 up to +60°C

Three detector types available

Flange process connection type II

  • Size: DN 6 to DN 500
  • Nominal pressure : PN 10 to PN 100

Type: Neoprene, Diameter: DN 25 to 500, Fluid temperature: 0 to 80°C

Type: Hard rubber, Diameter: DN 25 to 500, Fluid temperature: 0 to 80°C

Type: PFA, Diameter: DN 6 to 10, Fluid temperature: -40 to 0 +150°C

Type: PTFE, Diameter: DN 15 to 500, Fluid temperature: -40 to +150°C

Type: Halar, Diameter: DN 300 to 500, Fluid temperature: -40 to +150°C

  • Electrodes material : Hastelloy C (Standard), Tantal, Platinum / Gold plated, Platinum / Rhodium
  • Flange connection DIN, ANSI, JIS, AWWA, etc
  • Dimension according to ISO 13359,
  • Empty pipe electrode as Standard,
  • Ground electrode in the same material than the measurement electrode
  • Ground ring in option
  • IP67 or IP68 protection in option.

Wafer connection type III

  • Size : DN 25 to DN 100,
  • Nominal pressure : PN 40,
  • Linear materiel : PTFE,
  • Fluid temperature : -40 to +150°C,
  • Electrodes material : Hastelloy, Tantal, Platinum / Gold plated or Platinum / Rhodium
  • Protection class : IP65 or IP68 in option.

Sanitary detector for food

  • Size: DN 10 to DN 100,
  • Nominal pressure : PN40
  • Linear material : PTFE
  • Electrodes material : Hastelloy C (standard), Tantal, Platinum / Gold plated or Platinum / Rhodium
  • Housing : stainless stell
  • Lay : Tri-Clamp connection, ISO 2852 or SMS DIN 11851 connection
  • Protection class : IP65 or IP68 in option.
Zusatzinformationen